http://stardent2008.en.made-in-china.com/


http://stardent.en.alibaba.com/
星辰
Chinese  中文版 English  ENGLISH
Product Search :
Contact Us

Mobile: +86-18029290412 (WeChat/WhatsApp)
E-mail: info@stardentequ.com
Add:No.106,Zidong south road,Nanzhuang,Chancheng area,Foshan,Guangdong,China
Contact: Ms Sophie

Online Service

Skype:sophieyi0220   stardent@outlook.com
QQ:2294869173  281934541
WhatsApp:086-18029290412
Skype: zzlinker Skype: zzlinker

Pay attention to us

Home  »  products  »  Dental Handpiece  »  Low Speed Handpiece
Product name : SD-H206 Dental Handpiece 20: 1 Implant
Item : Low Speed Handpiece
 Enlarge Image                   Back


Details:
Available for various E type motors in accordance with ISO standard
Compatible with all E-type motors (NSK, Aseptico, W&H Nouvag, Acteon)

Dental handpieces right use way:
1. The need to use a clean , dry , oil-free air compressors for medical use ;
2. The air pressure between 2.3-2.8kgf / cm2;
3. Place the adapter with quick connector at the bottom of a combination of dental handpieces , and confirm that the card lock fixed ;
4. Press the pedal , handpiece operation and examine whether the normal operation of the spray head . If everything is normal, you can start using the handpiece.
After each patient use , maintenance should be done as follows
1. First remove the diamond burs , and clean up all the teeth on dental handpieces precipitate ;
2. Use a metal needle to clean the spray holes and fumaroles ;
Note: The spray holes and diamond burs into 40 -degree angle , fumaroles and diamond burs to a 30 degree angle.
3. Place the clean lubricating oil is sprayed into the axial hole 1-2 seconds ( diamond burs is plugged holes ) ;
4. In the bottom of the handpiece were ( with / without quick connector ) two kinds of styling , make the right amount of lubricant is injected into the bottom ;
5. The handpiece with quick connector combination ( first determine the water switch is turned off )
6. Replace the diamond burs , surrounded by white silk cloth handpiece head ( make sure the needle does not touch the diamond burs and white gauze , so as not to tie ) ;
7. pedal depressed for about 20 seconds , look at whether there is in white gauze on any stain. If there are stains on the white gauze , again, add oil , starting from item 4 continued routine maintenance , know that white gauze until no stain ;
8. Finally, no more than 135 degrees Celsius temperature and high pressure sterilization.

Related Products :

Data update...